Showing 1–16 of 17 results
4-20 mA Controller/Alarm/Indicator
Model : CT-2012
* Input : 4-20 mA DC, linear.
* User can default the desired display value between -1999 to 9999 ( decimal point can be selected to DP1, DP2, DP3 ) and all the preset data will be saved into the memory circuit permanently.
* When CT-2012 cooperates with LUTRON’S 4 TO 20 mA transmitters, whole system will become the high performance Controller/Alarm/Indicator for following measuring functions : Humidity, Light, pH, Dissolved Oxygen, Conductivity, Vibration, Pressure, Sound, Temperature, RPM, Hz, Load cell ( Weight, Force ), Potential ( Angle, Level ). ACV, ACA, DCV, DCA, WATT….
AC CURRENT
AC VOLTAGE
RPM CONTROLLER / MONITOR
MODEL : PDT-2250
* 10 to 99,990 RPM ( 0.1 rpm, <1,000 rpm ).
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 260 ACV, 50/60 Hz.
* RS-232/USB computer interface.
POWER FACTOR CONTROLLER/MONITOR
Model : PPF-6066
* Power factor Measurement range : 0.10 to 1.00 PF.
* Resolution : 0.01 PF ( power factor ).
* Signal input :
ACV : 0 to 600 ACV, 40 to 400 Hz.
ACA : 0 to 10 A, 40 to 400 Hz.
PH CONTROLLER/MONITOR
Model : PPH-2108
* 0 to 14 pH x 0.01 pH.
* ATC ( automatic temperature compensation ).
* Manual temperature compensation adjustment.
* pH control setting setting, Temp. control setting.
* pH control relay output, Temp. control relay output.
PRESSURE CONTROLLER/MONITOR
Model : PPS-9312
* Meter connects with 2, 5, 10, 20, 50, 100, 400 bar sensor, no calibration procedures are necessary when changing a new sensor.
* Unit select : BAr , PSI, Kg/cm2, inch Hg, mm Hg, inch H2O, Meter H2O, Atmosphere.
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
RS-232 CONTROLLER/ MONITOR
Model : PRS-2321
* Cooperate the LUTRON instruments ( build in the RS232 interface ), the panel meter will show all the measuring value.
* U 1 control setting, U2 control setting.
* U1 control relay output, U2 control realy output.
* U1, U2, U3 display.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
TEMPERATURE CONTROLLER/MONITOR
Model : PTM-9957
* Temp. sensor : type K/J/T/E/R/S thermocouple, Pt 100 ohm.
* Type K range : -100 to 1300 °C, °C/°F.
Type J range : -100 to 1200 °C, °C/°F.
Type T range : -100 to 400 °C, °C/°F.
Type E range : -100 to 900 °C, °C/°F.
Type R range : 0 to 1700 °C, °C/°F.
Type S range : 0 to 1500 °C, °C/°F.
Pt 100 ohm range : -199 to 850 °C, °C/°F.
* Resolution : 0.1 degree ( < 1000 degree )
1 degree ( ≥1000 degree )
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS-232/USB computer interface.
* DIN size : 96 x 48 mm. Depth : 107 mm.
* Optional type K probe : TP-01, TP-02A, TP-03, TP-04, TP-05.
* Optional Pt probe : TP-100B.
* Optional USB cable, USB-01.
* Optional data acquisition software, SW-U801-WIN, SW-E802.
TEMPERATURE CONTROLLER/MONITOR
Model : PTM-9957
* Temp. sensor : type K/J/T/E/R/S thermocouple, Pt 100 ohm.
* Type K range : -100 to 1300 °C, °C/°F.
Type J range : -100 to 1200 °C, °C/°F.
Type T range : -100 to 400 °C, °C/°F.
Type E range : -100 to 900 °C, °C/°F.
Type R range : 0 to 1700 °C, °C/°F.
Type S range : 0 to 1500 °C, °C/°F.
Pt 100 ohm range : -199 to 850 °C, °C/°F.
* Resolution : 0.1 degree ( < 1000 degree )
1 degree ( ≥1000 degree )
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS-232/USB computer interface.
* DIN size : 96 x 48 mm. Depth : 107 mm.
* Optional type K probe : TP-01, TP-02A, TP-03, TP-04, TP-05.
* Optional Pt probe : TP-100B.
* Optional USB cable, USB-01.
* Optional data acquisition software, SW-U801-WIN, SW-E802.
APPARENT POWER CONTROLLER/MONITOR
Model : PVA-6067
* Measurement range ( no cooperate with the external CT and the PT ) :
VA : 0 to 6,000 VA.
ACV : 0 to 600 ACV, 40 to 400 Hz.
ACA : 0 to 10 A, 40 to 400 Hz.
* True rms for VA measurement.
* Current input can cooperate with the external CT ( Current transformer ) such as CT 1000/5A, CT 100/5A …to expand the measurement range. The PT range can be adjusted with default.
* Control setting, Hi/Lo alarm setting.
* Control setting relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS232/USB computer interface.
APPARENT POWER CONTROLLER/MONITOR
Model : PVA-6067
* Measurement range ( no cooperate with the external CT and the PT ) :
VA : 0 to 6,000 VA.
ACV : 0 to 600 ACV, 40 to 400 Hz.
ACA : 0 to 10 A, 40 to 400 Hz.
* True rms for VA measurement.
* Current input can cooperate with the external CT ( Current transformer ) such as CT 1000/%A, CT 100/5A …to expand the measurement range. The PT range can be adjusted with default.
* Control setting, Hi/Lo alarm setting.
* Control setting relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS232/USB computer interface.
POWER CONTROLLER/MONITOR
Model : PWA-6065
* Measurement range ( no cooperate with the external CT and the PT ) :
Watt : 0 to 6,000 Watt.
ACV : 0 to 600 ACV, 40 to 400 Hz.
ACA : 0 to 10 A, 40 to 400 Hz.
* True rms for WATT measurement.
* Current input can cooperate with the external CT ( Current transformer ) such as CT 1000/5A, CT 100/5A …to expand the measurement range.
The PT range can be adjusted with default.
* voltage input can be adjusted with the external PT ( voltage transformer ) to expand the measurement range. The PT range can be adjusted with defaultt.
* Control setting, Hi/Lo alarm setting.
* Control setting relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS232/USB computer interface.
TP-07A (TEMP PROBE FOR PPH-2018, 0 TO 60 C)
Model : TP-07A (TEMP PROBE FOR PPH-2018, 0 TO 60 C)
FEATURE :
* Power : DC 9V to 30V.
* Precision ceramic type pressure sensor.
* External zero and span adjustment.
* Output with socket, easy replacement.
* Allow high cable load resistance, transmitter can be installed far away from the controller/indicator.
* Protection for the reverse wires connecting.
* Except MPS-384SD, TR-PS2W also can cooperate the " Pressure controller/monitor, PPS-9312 " or the " 4-20 mA Controller/Alarm/Indicator CT-2012 ".