Showing 1–16 of 22 results
4-20 mA Controller/Alarm/Indicator
Model : CT-2012
* Input : 4-20 mA DC, linear.
* User can default the desired display value between -1999 to 9999 ( decimal point can be selected to DP1, DP2, DP3 ) and all the preset data will be saved into the memory circuit permanently.
* When CT-2012 cooperates with LUTRON’S 4 TO 20 mA transmitters, whole system will become the high performance Controller/Alarm/Indicator for following measuring functions : Humidity, Light, pH, Dissolved Oxygen, Conductivity, Vibration, Pressure, Sound, Temperature, RPM, Hz, Load cell ( Weight, Force ), Potential ( Angle, Level ). ACV, ACA, DCV, DCA, WATT….
ACA TRANSMITTER
Model : TR-ACA1A4
* Range : 1A/5 A, isolated.
* Output : 4 to 20 mA, DC.
* Power : 90-260 ACV.
ACV TRANSMITTER
Model : TR-ACV1A4
* Range : 150/300 ACV, isolated.
* Output : 4 to 20 mA, DC.
* Power : 90-260 ACV.
ANEMOMETER TRANSMITTER
Model : TR-AMT1A4
* Range : 30 m/s.
* Output : 4 to 20 mA, DC.
* Power : 90-260 ACV.
CONDUCTIVITY TRANSMITTER
Model : TR-CDT1A4
* Range : 200 uS/2 mS/20 mS.
* Output : 4 to 20 mA, DC.
* Power : 90-260 ACV.
2000A DC/AC CLAMP TRANSMITTER
Model : TR-CLP1A4
* Range : 200/2,000 A, DC/AC.
* Output : 4 to 20 mA, DC.
* clamp probes is included.
* Power : 90-260 ACV.
DCA TRANSMITTER
Model : TR-DCA1A4-xxA
* Range : 200 uA, 2 mA, 20 mA, 200 mA, 2 A, 5 A, isolated.
* Output : 4 to 20 mA, DC.
* Power : 90-260 ACV.
DCV TRANSMITTER
Model : TR-DCV1A4-xxV
* Range : 200 mV, 2 V, 20 V, 200 V, isolated.
* Output : 4 to 20 mA, DC.
* Clamp adapter included.
* Power : 90-260 ACV.
DISSOLVED OXYGEN TRANSMITTER
Model : TR-DOT1A4
* Range : 0 to 20 mg/L.
* Output : 4 to 20 mA, DC.
* Power : 90-260 ACV.
HUMIDITY TRANSMITTER
Model : TR-HUM1A4
* Range : 10 % RH to 95 %RH.
* Output : 4 to 20 mA, DC.
* Power : 90-260 ACV.
FREQUENCY TRANSMITTER
Model : TR-HTZ1A4
* Range : 45 to 65 Hz.
* Output : 4 to 20 mA, DC.
* Power : 90-260 ACV.
LOAD CELL TRANSMITTER
Model ; TR-LDT1A4
* 1 to 2 mV/V, exciting DC 4V to 12 V.
* Output : 4 to 20 mA, Dc.
* Power : 90-260 ACV.
LIGHT TRANSMITTER
Model : TR-LXT1A4
* Range : 2,000/20,000/50,000 Lux.
* Output : 4 to 20 mA, Dc.
* Power : 90-260 ACV.
pH TRANSMITTER
Model : TR-PHT1A4
* Range : 0 to 14 pH.
* Output : 4 to 20 mA, DC.
* Power : 90-260 ACV.
2 WIRES PRESSURE TRANSMITTER
Model : TR-PS2W-xxBAR
* Range : 2,5,10,20,50,100,400 BAR.
* Output : 4 to 20 mA DC.
4 mA = 0 pressure, 20 mA = full scale pressure.
* 2 wires, both for signal and power source from MPS-384SD.* Power : DC 9V to 30V.
* Precision ceramic type pressure sensor.
* External zero and span adjustment.
* Output with socket, easy replacement.
* Allow high cable load resistance, transmitter can be installed far away from the controller/indicator.
* Protection for the reverse wires connecting.
* Except MPS-384SD, TR-PS2W also can cooperate the " Pressure controller/monitor, PPS-9312 " or the " 4-20 mA Controller/Alarm/Indicator CT-2012 ".
POTENTIAL TRANSMITTER
Model : TR-PTT1A4
* 200 to 50 kohm, exciting DC9V.
* Output : 4 to 20 mA, DC.
* Power : 90-260 ACV.