Showing all 12 results
Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696
Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696
Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696
PRECISION HUMIDITY + TEMP, + DEW POINT
Model : HT- 3009
* 1000 Data logger no., RS-232/USB interface
* Resolution : 0.01 %RH, 0.01 degree
* 4 sec. , fast humidity response time
* 2 % RH humidity accuracy, high precession.
* The best professional hygrometer.
PROFESSIONAL PHASE ROTATION TESTER
Model : WI-5801
Operation Voltage : 60-600V AC three phase
Sequence Use : 2000V AC : 30 Minutes
Time Limit : 480V AC : 4 Minutes/600V AC : 2 Minutes
Frequency Range : 20Hz-400Hz
Withstand Voltage : 2000V/min
Test Leads : Double Insulted Wires,
About One Meter Length
COLOR ANALYZER, probe + meter, RS232
Model : RGB-1002
* Measuring sample : no lighting sample ( textiles, paper, leathers… ).
* Measurement value : RGB value, HSL value ( Hue/Saturation/Luminance ).
* R ( Red ) value : 0 to 1023.
G ( Green ) value : 0 to 1023.
B ( Blue ) value : 0 top 1023.
* 45° /0° color measuring geometry.
* Used the spectral analysis method to determine the color of the sample.
* Complete set included the color probe and the meter, show RGB or HSL value at same time.
* RS232/USB computer interface.
* Power : 006P DC 9V battery.
* Meter size : 203 x 76 38 mm.
Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696
Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696HOT WIRE ANEMOMETER, air flow
Model : YK-2004AH
* Air velocity, Air flow ( CMM, CFM ), Temperature.
* Hot wire anemometer, high precision for low air velocity measurement.
* Telescope and seperate probe, easy operation.
* 0.2 to 20.0 m/s. CNN, CFM.
Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696
Real time data logger, + air flow, + type K/J HOT WIRE ANEMOMETER
Model : YK-2005AH
* High capacity ,16,000 data logger point.
* Real time data logger(record year,month,date,hour,minute,second).
* Air velocity, Air flow, Temp., type K/J Temp..
* Hot wire anemometer, high precision for low air velocity measurement,Telescope probe.
Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696
ANEMOMETER,Real time data logger+air flow
Model : YK-2005AM
* High Capacity,16,000 data logger point
* Real time data logger(record year,month,date,hour,minute,second)
* Air velocity ,Air flow,Temp.,type K Temp
* Metal vane,heavy duty
Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696
CONDUCTIVITY METER
Model: YK-2005CD
* High capacity, 16000 data logger no.
* Real time data logger(record year,month,date,hour,minute,second).
* Range : 200 uS/ 2 ms/20 ms/200 mS.
* Automatic temp compensation atc factor adj.
* Carbon rod electrode for long life.
Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696LIGHT METER, Real time data logger
Model : YK-2005LX
* High capacity, 16,000 data loggert point.
* real time data logger ( Record year, month, date, hour, minute, second ).
* Range : 200/2,000/20,000/100,000 Lux.
* Unit : Lux, Feet-candle.
Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696
Real time data logger Multi-function THERMOMETER
Model : YK-2005TM
* High capacity, 16,000 data logger point.
* Real time data logger ( record year, month, date, hour, minute, second ).
* multi-function : Type K, Type J, Pt100 ohm, Infrared Thermometer.
* Type K : -100 to 1300 °C, Type J : -100 to 1100 °C, Pt 100 ohm -200 to 850 °C.
Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696
PH/ORP, DO CD/TDS METER
Model : YK – 2005WA
* One meter for multi purpose operation :
* pH : 0 to 14.00 pH , ORP : + 1999 mV .
* Dissolved oxygen : 0 to 20.0 mg/L .
* ATC ( automatic temperature compensation ) .