Description
POWER ANALYZER , bench type
Model : DW – 6090
Large LCD , multi-displays.
True rms for WATT, ACV, ACA.
Watt , VA , Power factor , ACV, ACA , DCV , DCA,
VAr, Whr , ohms, RS232/USB interface.
Accept current probe & CT input . Battery power
₹32,200.00 (18% GST Extra)
Shipping charges are applicable
POWER ANALYZER , bench type
Model : DW – 6090
Large LCD , multi-displays.
True rms for WATT, ACV, ACA.
Watt , VA , Power factor , ACV, ACA , DCV , DCA,
VAr, Whr , ohms, RS232/USB interface.
Accept current probe & CT input . Battery power
POWER ANALYZER , bench type
Model : DW – 6090
Large LCD , multi-displays.
True rms for WATT, ACV, ACA.
Watt , VA , Power factor , ACV, ACA , DCV , DCA,
VAr, Whr , ohms, RS232/USB interface.
Accept current probe & CT input . Battery power
Flexible 3000 Amp current probe
Model : CP-3000-B ( blue connector )
* Range : 30 A/300 A/3000 A.
* Output sensitivity :
100 mV/A, 10 mV/A, 1 mV/A.
* Output voltage :
3 ACV ( 30 A, 300 A, 3000A ).
* Flexible probe length : 600 mm ( 23.6 inch ).
Flexible probe diameter : 15 mm.
POWER CONTROLLER/MONITOR
Model : PWA-6065
* Measurement range ( no cooperate with the external CT and the PT ) :
Watt : 0 to 6,000 Watt.
ACV : 0 to 600 ACV, 40 to 400 Hz.
ACA : 0 to 10 A, 40 to 400 Hz.
* True rms for WATT measurement.
* Current input can cooperate with the external CT ( Current transformer ) such as CT 1000/5A, CT 100/5A …to expand the measurement range.
The PT range can be adjusted with default.
* voltage input can be adjusted with the external PT ( voltage transformer ) to expand the measurement range. The PT range can be adjusted with defaultt.
* Control setting, Hi/Lo alarm setting.
* Control setting relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS232/USB computer interface.
1200 Amp current probe
Model : CP-1201
* Range : 20 A/200 A/1200 A.
* Output sensitivity :
10 mV/A, 1 mV/A, 0.1 mV/A.
* Output voltage :
200 AcmV ( 20 A. 200 A ), 120 ACmV ( 1200 A ).
* Max. conductor size : 48 mm ( 1.9 inch ) Dia.
* Operation frequency : 50 Hz/60 Hz.
99.99 x 0.01 W, 520.0 x 0.1 W, PF, ACV, ACA, Signal phase Precision Watt Meter
Model : DW-6063
* 0.01 W resolution, precision Watt meter is special for low power measurement.
* Designed for the high resolution low power measurement.
* Watt, Power factor, ACV, ACA.
* True Power ( watt ) measurement.
* True rms measurement for ACV, ACA.