PAV-6068 (AC VOLTAGE CONTROLLER/ MONITOR, 0 TO 600ACV, RS-232/USB)

 AC Voltage CONTROLLER/MONITOR

Model : PAV-6068

* Measurement range ( no cooperate with the external PT ) : ACA : 0 to 600 ACV, 40 to 400 Hz.

* True rms for ACA measurement.

* Voltage input can cooperate with the external PT ( voltage transformer ) to expend the measurement range. the PT range can be adjusted with setting.

* Control setting, Hi/Lo alarm setting.

* Control realy output, alarm relay output.

AVAILABILITY: In stock

PRICE : INR 11160.00
QTY : 1
Delivery Within : 15 TO 20 WORKING DAYS

Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696
Rating Review ()
   
Name :
Email :
Rating :
Name :
Email :
Review :

 AC Voltage CONTROLLER/MONITOR

Model : PAV-6068
FEATURES
* Professional ACV meter with standard DIN case ( 96 x Over input " - - - - " mark indication.
48 mm ) and Control/Alarm function. Zero Automatic adjustment.
* Microprocessor circuit ensures high accuracy and Adjustment
provide special functions and features. Data Output RS232 / USB PC Computer interface.
* Large red LED display, high brightness and easy to read. * Connect the optional RS232 cable ,
* Input signal ( without PT ) : UPCB - 02 will get the RS232 plug.
ACV : 1.0 to 600.0 ACV, 40 to 400 Hz. * Connect the optional USB cable,
* True rms for ACV measurement. USB - 01 will get the USB plug.
* Voltage input can cooperate the external PT ( Potential Operating perating 0 to 50 ℃.
transformer ) to expend the measurement range. The Temperature
PT range can be adjusted with default. Operating Less than 80% R.H.
* Control setting, Hi/Lo alarm setting. Humidity
* Control relay output, alarm relay output. Power Supply 90 to 260 ACV, 50/60 Hz.
* Control Relay will make action when the reading value Power Approx. 3.3 VA/AC 110V.
reach to control value. Consumption Approx. 4.9 VA/AC 220V.
* Alarm Relay will make action when the reading value * Under no load
reach to high/low alarm value. Weight 261 g/ 0.57 LB.
* Hysteresis value setting for control and alarm function. Dimension DIN size : 96 x 48 mm.
* Power : 90 ACV to 264 ACV, 50/60 Hz. Panel cut size : 92 x 46 mm.
* RS232/USB computer interface. Depth : 110 mm.
* Option data acquisition software. Accessories Instruction manual....................... 1 PC
Included Case holder with screw.................2 PCs
GENERAL SPECIFICATIONS Optional USB cable , USB - 01
Display Large LED display. 4 digit LED . Accessories RS232 cable , UPCB - 02
14 mm ( 0.55 inch ) digit height . Data Acquisition software SW-U801-WIN
5 indicators . * Real time SD card datalogger
PV ( process value ) indicator DL-9602SD
SV ( set value ) indicator * GSM controller, GSM-889.
Control out indicator * Interface cable ( cable between meter
Alarm out indicator to GSM-889 ), GMCB-89.
V ( ACV ) indicator
Circuit Custom chip of microprocessor LSI ELECTRICAL SPECIFICATIONS
circuit.
ACV 1.0 ACV to 600.0 ACV Without PT( direct input )
measurement * True rms value
* Without PT. Range 1 ACV to 600 ACV
Sampling Time Approx. 0.8 second. Resolution 0.1 ACV
Relay Output Number 2 relays Accuracy ± ( 0.5 % + 5d ) reading
Function Relay 1 : Remark :
Control relay. * Measuring Signal come from the rear terminals .
Relay 2 : * T11, T12 max. ACV input : AC 600 V .
High/Low alarm relay. * Accuracy is test under input signal is sine wave, 50/60 Hz.
Max load 0.5 ACA/250 ACV * ACV frequency response is from 40 to 400 Hz.
0.5 DCA/24 DCV * ACV measurement is True RMS value.
* Do not apply the relay * Accuracy value is specified within 23℃ ± 5℃
contact load current
> 0.5 A, other wise the With PT ( Potential transformer )
relay may be damaged
permanently without Range 10 ACV to 9999 ACV
warranty. Resolution 1 ACV
Setting 1st layer CtLo ( Control low limit ) Accuracy ± ( 0.5 % + 5d ) reading
Function setting CtHi ( Control high limit ) Remark :
procedures ALLo ( Alarm low limit ) * Measuring Signal come from the rear terminals .
ALHi ( Alarm high limit ) * T11, T12 max. ACV input : AC 600 V .
Second layer PtSt ( PT rate setting ) PT ( Potential transformer ) adjust value : x 1 to x 100.
setting CtHy ( Control hysteresis value * Accuracy is test under input signal is sine wave, 50/60 Hz.
procedures setting ) * Accuracy is specified for the meter only, not include the accuracy
ALHy ( Alarm hysteresis value of PT ( Potential transformer ).
setting )
 