DL-9602SD (SD CARD DATA RECORDER, CAPACITY: 1 GB TO 16 GB, MAX 9 CHANNELS DATA INPUT, RS-232/USB)

Real time data recorder SD CARD DATA LOGGER

Model : DL-9602SD

* Real time SD memory card Datalogger, it can cooperate with most LUTRON instruments if it is built-in the computer interface.

* Innovation and easy operation, computer is not need to setup extra software, just take away the SD card from the DL-9602SD and plug it into the computer, then the measured values with the time information ( year/month/date/hour /minute/second ) can be downloaded to the Excel directly. User can make the future data or graphic analysis in the Excel by themselves.

* Built-in Clock and Calendar, real time data recorder, sampling time can be set from 2 seconds to 8 hours 59 minutes 59 seconds.

* Manual datalogger is available ( set the sampling time to 0 ), during executing the manual datalogger function, it can set the different place location No.( place 1 to place 99 ).

* Signal input : Accept CM-9930R's RS232 signal via interface cable UPCB-03.

* SD card ( optional ) capacity : 1 GB to 16 GB.

* DC 1.5V battery ( UM-3, AA ) x 6 or DC 9V adapter in.

* LCD with green light backlight, easy reading.

 

 

AVAILABILITY: out of stock

PRICE : INR 13110.00
QTY : 1
Delivery Within : 15 TO 20 WORKING DAYS.

Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696
Rating Review ()
   
Name :
Email :
Rating :
Name :
Email :
Review :

Real time data recorder SD CARD DATA LOGGER

Model : DL-9602SD

FEATURES
* Real time SD memory card Datalogger, it can Advanced * SD memory card Format
cooperate with most LUTRON instruments if it build setting * Set input channel No.
in the computer interface. Set clock time ( Year/Month/Date,
* Built-in Clock and Calendar, real time data Hour/Minute/ Second )
recorder , sampling time set from 1 second to 8 * Set sampling time ( Hour/Minute/
hours 59 minutes 59 seconds. Second )
* Manual datalogger is available ( set the sampling * Auto power OFF management
time to 0 ), during execute the manual datalogger * Set LCD backlight ON/OFF
function, it can set the different place ( location ) No. * Set beeper sound ON/OFF
( place 1 to place 99 ). Power off Auto shut off saves battery life or
* Innovation and easy operation, computer is not manual off by push button.
need to setup extra software, after execute Sampling Time Auto 2 seconds to 8 hours 59 min.
datalogger, just take away the SD card from the Setting range 59 seconds.
meter and plug in the SD card into the computer, @ Sampling time can set to 1 second,
it can down load the measured value with the but memory data may loss
time information ( year/month/date/ Manual Push the data logger button
hour/minute/second ) to the Excel directly, then once will save data one time.
user can make the further data or graphic @ Set the sampling time to
analysis by themselves. 0 second.
* SD card capacity : 1 GB to 16 GB. Data error no. 0.1% of total saved data max.
* Can set the numerical decimal point character to " . " Data Output RS 232/USB PC computer interface.
or " , " with default, then Datalogger data that saved * The output data structure are same as
into the SD card can be used in different country. the input data.
* Can set max. 9 channels data input with default. * Connect the optional RS232 cable
* DC 1.5V battery ( UM-3 , AA ) x 6 or DC 9V UPCB-02 will get the RS232 plug.
adapter in. * Connect the optional USB cable
* LCD with green light backlight, easy reading. USB-01 will get the USB plug.
* RS232 signal output, can connect the external Operating 0 to 50 ℃.
computer. Temp. and Less than 85% R.H.
Humidity
SPECIFICATIONS Power Supply * AAClk/aDlCin ep oowr ehre advya pdtuetry i sD oCp 1ti.o5n Val .battery
Application * Real time SD memory card ( UM3, AA ) x 6 PCs, or equivalent.
Datalogger can cooperate with all * ADCC/ D9CV paodwapetre ar dinaputetr. (is A oCp/tDioCn aplo.wer
LUTRON instruments if it build in adapter is optional ).
the computer interface. Power Current Normal operation ( w/o SD card save
* Innovation and easy operation, data and LCD Backlight is OFF) :
computer no need to setup extra Approx. DC 7 mA.
software, after execute datalogger, just When SD card save the data and LCD
plug in the SD card into the computer, Backlight is OFF) :
it can down load the all the measured Approx. DC 28 mA.
value and unit along with the time * AIfC L/DCCD pboawckelirg ahdt aopnt,e rt hise oppotwioenral.
information ( year/month/date/ consumption will increase approx.
hour/minute/second ) to the Excel 17 mA.
directly, user can make the further data Weight 468 g/1.03 LB.
or graphic analysis by themselves. Dimension 178 x 68 x 44 mm
Circuit Custom one-chip of microprocessor LSI (7.0 x 2.7x 1.7 inch)
circuit. Standard * Instruction manual..........................1.. .P..C.......
Display LCD size : 52 mm x 38 mm Accessories * Double earphone cable, UPCB-03
LCD with Backlight ( ON/OFF ). Included .....................................................1.. .P.C....
Input Direct RS232 signal input. Optional Hard carrying case, CA-06
Signal Isolate RS232 signal input. Accessory
PATENT CHINA : ZL 2008 2 0189918.5 ZL 2008 2 0189917.0 TAIWAN : M 358970 M 359043

 

Germany : Nr. 20 2008 016 337.4 JAPAN : 3151214 U.S.A. : Pending.

 

 

 



RECENTLY VIEWED PRODUCTS