9 in 1
Anemometer, Humidity/Temp. meter,
UV Light meter, Pt 1000 Temp. ( optional )
Sport/Weather meter
ENVIRONMENT METER
Model : SP-8002
FEATURES
* 9 in 1 professional environment instruments: Humidity/Temp.
1. Air velocty/Temp., 2. Humidity/Temp., 3. UV Light
4. CFM, CMM, 5. Dew point, 6. Wet bulb, 7. Wind chill, Unit Range Resolution Accuracy
8. Heat index, 9. Pt 1000 ohm Temp.( optional ) % RH 10 to 95 %RH 0.1 %RH < 70% RH :
* Tiny bone shape with light weight and small size case ± 4 %RH
design are suitable for handling with th one hand. ≧70% RH :
* Wristlet design provides extra protection to the ± ( 4 %rdg +1.2 %RH)
instrument especially for user one hand operation. Temp. 0 to 50 ℃ 0.1 ℃ ± 1.2 ℃
* Low-friction ball bearing mounted wheel design 32 to 122 ℉ 0.1 ℉ ± 2.5 ℉
provides high accuracy at high and low air velocity.
* UV sensor structure The exclusive UV photo sensor with UV Light * auto range * UVA light measurement
the cosine correction filter.
* High precision humidity sensor with fast response time. Range Resolution Accuracy
* Optional Pt 1000 ohm Temp. probe for the prcision 0 to 1999 uW/cm^2 1 uW/cm^2 ± ( 4 % FS + 2 dgt )
Temp. measurement. 2 to 20.00 mW/cm^2 0.01 mW/cm^2 FS : full scale
* Built- in microprocessor circuit assures excellent Remark
performance and accuracy. * Calibration is executed under the UVA light & and compare with
* Concise and compact buttons arrangement, the standard UVA light meter.
easy operation. * UV Sensor structure :
* Memorize the maximum and minimum value with recall. The exclusive UV photo sensor with the cosine correction filter.
* ℃/℉ detection by pressing button on the front panel. * UV sensor spectrum Band pass 290 nm to 390 nm.
* Hold function to freeze the current reading value.
Pt 1000 ohm Thermometer ( optional probe )
GENERAL SPECIFICATIONS
Display 8 mm LCD display Unit Range Resolution Accuracy
Measurement 1. Air velocty/Temp. ℃ -10.0 to 70.0 ℃ 0.1 ℃ ± 1.2 ℃
2. Humidity/Temp. ℉ 14.0 to 158.0 ℉ 0.1 ℉ ± 2.5 ℉
3. UV Light
4. CFM, CMM Dew point Temp.
5. Dew point
6. Wet bulb Unit Range Resolution Remark
7. Wind chill ℃ -25.3 to 49.0 ℃ 0.1 ℃ * Calculate from the
8. Heat index ℉ -13.5 to 120.0 ℉ 0.1 ℉ humidity/Temp. value
9. Pt 1000 ohm Temp.( optional ) Please refer to http://en.wikipedia.org/wiki/Dew_point
Operating Max. 80% RH.
Humidity Wet bulb Temp.
Operating 0 to 50 ℃ ( 32 to 122 ℉ )
Temperature Unit Range Resolution Remark
Over Input Indication of "- - - - " ℃ -5.4 to 49.0 ℃ 0.1 ℃ * Calculate from the
Display ℉ 22.2 to 120 ℉ 0.1 ℉ humidity/Temp. value
Power Supply CR 2032 DC 3V battery Please refer to http://en.wikipedia.org/wiki/Wet-bulb_temperature
Power Approx. DC 5 mA
Consumption Heat index
Weight 160g (battery included)
Dimension HWD 120 x 45 x 20 mm (4.7 x 1.8 x 1.2 inch). Unit Range Resolution Accuracy
Standard Instruction Manual ℃ 0 to 70.0 ℃ 0.1 ℃ ± 2.0 ℃
Accessory ℉ 32 to 158 ℉ 0.1 ℉ ± 3.6 ℉
Optional Pt 1000 ohm Temp. probe, TP-1000 Pleas refer to http://en.wikipedia.org/wiki/Heat_index
Accessories
Effects of the heat index (shade values)
ELECTRICAL SPECIFICATION ( 23 ± 5℃ ) Celsius Fahrenheit Notes
27– 32 ℃ 80– 90 ℉ Caution :
Air velocity Fatigue is possible with prolonged exposure
and activity. Continuing activity could result in
Unit Range Resolution Accuracy heat cramps
ft/min 80 to 3937 ft/min 1 ft/min 32– 41 ℃ 90– 105 ℉ Extreme caution :
m/s 0.4 to 20.0 m/s 0.1 m/s ≦ 20 m/s : ± 3% F.S. Heat cramps, and heat exhaustion are possible.
km/h 1.4 to 72.0 km/h 0.1 km/h > 20 m/s : ± 4% F.S. Continuing activity could result in heat stroke
MPH 0.9 to 44.7 mile/h 0.1 MPH 41– 54 ℃ 105– 130 ℉ Danger :
knots 0.8 to 38.8 knots 0.1 knots Heat cramps, and heat exhaustion are likely ;
Temp. 0 to 50 ℃ 0.1 ℃ heat stroke is probable with continued activity
32 to 122 ℉ 0.1 ℉ over 54 ℃ over 130 ℉ Extreme danger : Heat stroke is imminent
Remark : Note :
ft/min : feet per minute MPH : miles per hour Exposure to full sunshine can increase heat index values by up to
m/s : meters per second knots : nautical miles per hour 8 ℃ ( 14℉ ).
km/h : kilometers per hour
Wind chill
Ar flow
Unit Range Resolution Accuracy
Unit Range Resolution ℃ -0.4 to 44.2 ℃ 0.1 ℃ ± 2.0 ℃
CMM 0.024 to 36000 0.001/0.01/0.1/1 ℉ 15.0 to 112.0 ℉ 0.1 ℉ ± 3.6 ℉
* Wind chill value is effect only when the Temp. value < 15 ℃ and
CFM 0.847 to 1271300 0.001/0.01/0.1/1/10 (x10)/100 (x100) Air velocity value > 1.4 m/s.
* Please refer to http://en.wikipedia.org/wiki/Wind_chill