FEATURES
* Complete set with two probes : Hot wire anemometer Operating 0 to 50 ℃.
probe and Humidity/Temp. probe. Temperature
* Combination of hot wire and standard thermistor, Operating Less than 85% R.H.
deliver rapid and precise measurements even at low Humidity
air velocity value. Power Supply * AAlkaline or heavy duty DC 1.5 V battery
* Slim probe, ideal for grilles & diffusers. ( UM3, AA ) x 6 PCs, or equivalent.
* Air velocity : m/s, Ft/min, Km/h, Knot, Mile/h, * ADC 9V adapter input. ( AC/DC power
* Air flow ( CFM, CMM ) measurement. adapter is optional ).
* Air temperature ( ℃, ℉ ) Power Current Normal operation ( w/o SD card save
* Air Temp. used thermistor sensor, fast response time. data and LCD Backlight is OFF) :
* Humidity : 10 to 95 %RH, Dew point, Wet bulb. Approx. DC 30 mA.
* Type K, Type J thermocouple thermometer. When SD card save the data and LCD
* Real time SD memory card Datalogger, it Built-in Clock Backlight is OFF) :
and Calendar, real time data recorder , sampling time set Approx. DC 50 mA.
from 1 second to 3600 seconds. Weight 347 g/ 0.76 LB. * Meter only
* Manual datalogger is available ( set the sampling Dimension Main instrument :
time to 0 ), during execute the manual datalogger 182 x 73 x 47.5 mm
function, it can set the different position ( location ) No. ( 7.1 x 2.9 x 1.9 inch )
( position 1 to position 99 ). Telescope Probe :
* Innovation and easy operation, computer is not need Round, 12 mm Dia x 280 mm ( min. length ).
to setup extra software, after execute datalogger, just Round, 12 mm Dia x 940 mm ( max. length ).
take away the SD card from the meter and plug in the Accessories * Instruction manual...........................1 PC
SD card into the computer, it can down load the all the Included * Hot wire telescope probe..................1 PC
measured value with the time information ( * Humidity/Temp. probe......................1 PC
year/month/date/ hour/minute/second ) to the Excel * Hard carrying case ..........................1 PC
directly, then user can make the further data or graphic Optional SD Card ( 2 G )
analysis by themselves. Accessories Type K thermocouple probe.
* SD card capacity : 1 GB to 16 GB. AC to DC 9V adapter.
* LCD with green light backlight, easy reading. USB cable, USB-01.
* Can default auto power off or manual power off. RS232 cable, UPCB-02.
* Data hold, record max. and min. reading. Data acquisition software, SW-U801-WIN.
* Microcomputer circuit, high accuracy. Excel 'data acquisition software, SW-E802.
* Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter.
* RS232/USB PC COMPUTER interface. ELECTRICAL SPECIFICATIONS (23± 5 ℃)
* Separate probe, easy for operation of different
measurement environment. Air velocity
* Applications : Environmental testing, Air conveyors,
Flow hoods, Clean rooms, Air velocity, Air balancing, Measurement Range Resolution Accuracy
Fans/motors/blowers, Furnace velocity, Refrigerated case, m/s 0.2 to 5.0 m/s 0.01 m/s ± ( 5% + a )
Paint spray booths. 5.1 to 25.0 m/s 0.1 m/s reading
Km/h 0.70 to 18.00 km/h 0.01 Km/h
GENERAL SPECIFICATIONS 18.0 to 72.0 km/h 0.1 Km/h or
Circuit Custom one-chip of microprocessor LSI Mile/h 0.50 to 11.20 mph 0.01 mph ± ( 1% + a )
circuit. ( mph ) 11.2 to 44.7 mph 0.1 mph full scale
Display LCD size : 52 mm x 38 mm Knot 0.40 to 9.70 knot 0.01 Knot
LCD with green backlight ( ON/OFF ). 9.7 to 38.8 knot 0.1 Knot
Function Anemometer ( Air velocity, Air flow ). Ft/min 40-3940 ft/min 1 Ft/min
Humidity/Temp. meter. @ a = 0.1 m/s, 0.3 km/h, 0.2 mile/h, 0.2 knot, 20 ft/min
Type J/K thermometer. Note:
Measurement Air velocity : m/s - meters per second km/h - kilometers per hour
Unit m/S (meters per second) ft/min - feet per minute knot - nautical miles per hour
Km/h ( kilometers per hour ) mile/h - miles per hour (international knot)
Ft/min ( FPM, feet per minute )
Knots ( nautical miles per hour ) Air temperature
Mile/h ( mph, miles per hour )
Air temperature :℃, ℉ Measuring Range 0 ℃ to 50 ℃/32 ℉ to 122 ℉
Air flow : CMM, CFM. Resolution 0.1 ℃/0.1 ℉
Humidity/Temp. : %RH/℃ or ℉. Accuracy ± 0.8 ℃/1.5 ℉
Dew point ( Humidity ) : ℃ or ℉.
Wet bulb ( Humidity ) : ℃ or ℉. Air flow
Type K/ Type J thermometer : ℃, ℉
Sensor Air velocity & Air flow : Measurement Range Resolution
Structure Tiny glass bead thermistor. CMM ( m^3/min. ) 0 to 45,000 CMM 0.001 to 1 CMM
Air temperature : CFM ( ft^3/min. ) 0 to 1,589,200 CFM 0.001 to 100 CFM
Thermistor.
Humidity : Measurement Area
Precision capacitance humidity sensor. CMM ( m^3/min. ) 0.001 to 30.000 m^2
Type K, Type J thermometer : CFM ( ft^3/min. ) 0.01 to 322.93 ft^2
Type K/J thermocouple probe.
* Probes are optional. Humidity/ Temperature
Datalogger Auto 1 second to 3600 seconds
Sampling Time @ Sampling time can set to 1 second, Range 5 % to 95 % R.H.
Setting range but memory data may loss. Humidity Resolution 0.1 % R.H.
Manual Push the data logger button Accuracy ≧70% RH :
once will save data one time. ± (3% reading + 1% RH).
@ Set the sampling time to < 70% RH :
0 second. ± 3% RH.
@ Manual mode, can also select the Range 0 ℃ to 50 ℃,32 ℉ to 122 ℉.
1 to 99 position ( Location ) no. Temperature Resolution 0.1 degree
Memory Card SD memory card. 1 GB to 16 GB. Accuracy ℃ ± 0.8 ℃.
* It recommend use memory card ≦ 4 GB. ℉ ± 1.5 ℉.
Advanced * Set clock time ( Year/Month/Date,
setting Hour/Minute/ Second ) Dew Point ( Humidity )
* Set sampling time
* Auto power OFF management ℃ Range -25.3 ℃ to 48.9 ℃
* Set beep Sound ON/OFF Resolution 0.1 ℃
* Decimal point of SD card setting ℉ Range -13.5 ℉ to 120.1 ℉.
* SD memory card Format Resolution 0.1 ℉.
* Set thermometer type to Type K or Type J Remark :
* Set temperature unit to ℃ or ℉ * Dew Point display value is calculated from the
* Set air flow type ( CFM/USA, CMM/EURO ) Humidity/Temp. measurement automatically.
* Set air flow area dimension * The Dew Point accuracy is sum accuracy value of
Temperature Automatic temp. compensation for the Humidity & Temperature measurement..
Compensation Anemometer function and the type K/J
thermometer. Wet bulb ( Humidity )
Data Hold Freeze the display reading.
Memory Recall Maximum & Minimum value. ℃ Range -21.6 ℃ to 50.0 ℃
Sampling Time Approx. 1 second. Resolution 0.1 ℃
of Display ℉ Range -6.9 ℉ to 122.0 ℉.
Data Output RS 232/USB PC computer interface. Resolution 0.1 ℉.
* Connect the optional RS232 cable Remark :
UPCB-02 will get the RS232 plug. *Wet bulb display value is calculated from the
* Connect the optional USB cable Humidity/Temp. measurement automatically.
USB-01 will get the USB plug. * The Welt bulb accuracy is sum accuracy value of
Humidity & Temperature measurement..
PATENT CHINA : ZL 2008 2 0189918.5 ZL 2008 2 0189917.0 TAIWAN : M 358970 M 359043
Germany : Nr. 20 2008 016 337.4 JAPAN : 3151214 U.S.A. : Pending.