MANOMETER
2000 mbar, dual & differential input
Model : PM-9100
FEATURES
* Dual & differential input, 2000 mbar max. range. * Push button gain adjustment, usage for calibration
* Application : Industrial, laboratory, heating, precisely if necessary.
ventilation, medical hospital, used for air or not * Microprocessor circuit assures maximum possible
corrosive and not ionized gas. accuracy, provides special functions and features,
* Sensor is built inside the housing. * Super large LCD display with contrast adjustment
* Single lugs for pipe connection. for best viewing angle.
* 8 kind display units ( m bar, psi, Kg/cm^2, mm/Hg, * Records maximum & minimum readings with recall.
inch/Hg, meter/H2O, inch/H20, Atmosphere ) select * Data Hold function for stored the desired value on
by push button on the front panel display.
* Auto shut off saves battery life. * Built-in low battery indicator.
* Zero button on the front panel, easy to offset the zero* RS 232 PC serial interface, can match the personal
value. computer used as the Data Logger, Recorder.... &
other modern pressure measuring system.
GENERAL SPECIFICATIONS
Circuit Microprocessor LSI circuit. Power off Auto shut off, saves battery life, or
Display 61 mm x 34 mm supper large LCD manual off by push button.
display. 15 mm ( 0.6" ) digit size. Sampling time Approx. 0.8 second.
Display units mbar, psi, Kg/cm^2, mm/Hg, inch/HgOperating 0 to 50 ℃ ( 32 to 122 ℉ ).
meter/H2O, inch/H2O, Atmosphere. temperature
Function Dual & differential input, data hold, Operating Less than 80% R.H.
zero/relative, memory. humidity
Zero adjust Push button on the front panel. Power supply 006P DC 9V battery(heavy duty).
Span adjust Push button gain adjustment, usage Power current Approx. DC 8.5 mA.
for calibration precisely if necessary. Weight 345 g/0.76 LB
Sensor * Sensor is built inside the housing. Dimension 180 x 72 x 32 mm
* Piezoelectric sensor. ( 7.1 x 2.8 x 1.3 inch )
* Used for dry, non-corrosive and Accessories * Instruction manual............. 1 PC.
non-ionic air and gas only. included * Hard carrying case.............. 1 PC.
* Liquid is prohibited. Optional * Data acquisition software
Data hold By push button. accessories ( Windows version ),
Data record Record maximum & minimum SW-U801-WIN
readings. * RS232 cable, UPCB-01
Data output RS 232 PC serial interface. * USB cable, USB-01
ELECTRICAL SPECIFICATIONS ( 23± 5 ℃)
Unit Max. range Resolution Accuracy
m bar 2000 m bar 1 m bar
psi 29 psi 0.01 psi
Kg/cm^2 2.040 Kg/cm^2 0.001 Kg/cm^2 ± 2 % F. S. ( F.S. : full scale )
mm/Hg 1500 mm/Hg 1 mm/Hg
inch/Hg 59.05 inch/Hg 0.02 inch/Hg Note :
meter/H2O 20.40 meter/H2O 0.01 meter/H2O Included linearity, hysteresis and
inch/H2O 802 inch/H2O 0.5 inch/H2O repeatability
Atmosphere 1.974 Atmosphere 0.001 Atmosphere