2000 mbar, dual & differential input
MANOMETER
Model : PM-9100HA
FEATURES
* Dual & differential input, 2000 mbar max. range. * Push button gain adjustment, usage for calibration
* Application : Industrial, laboratory, heating, precisely if necessary.
ventilation, medical hospital, used for air or not * Microprocessor circuit assures maximum possible
corrosive and not ionized gas. accuracy, provides special functions and features,
* Sensor is built inside the housing. * Super large LCD display with contrast adjustment
* Single lugs for pipe connection. for best viewing angle.
* 8 kind display units ( m bar, psi, Kg/cm^2, mm/Hg, * Records maximum & minimum readings with recall.
inch/Hg, meter/H2O, inch/H20, Atmosphere ) select * Data Hold function for stored the desired value on
by push button on the front panel display.
* Auto shut off saves battery life. * Built-in low battery indicator.
* Zero button on the front panel, easy to offset the * Hard carring case included.
zero value.
GENERAL SPECIFICATIONS
Circuit Microprocessor LSI circuit. Data record Record maximum & minimum
Display 61 mm x 34 mm supper large LCD readings.
display. 15 mm ( 0.6" ) digit size. Power off Auto shut off, saves battery life, or
Display units mbar, psi, Kg/cm^2, mm/Hg, inch/Hg, manual off by push button.
meter/H2O, inch/H2O, Atmosphere. Sampling time Approx. 0.8 second.
Function Dual & differential input, data hold, Operating 0 to 50 ℃ ( 32 to 122 ℉ ).
zero/relative, memory. temperature
Zero adjust Push button on the front panel. Operating Less than 80% R.H.
Span adjust Push button gain adjustment, usage humidity
for calibration precisely if necessary. Power supply 006P DC 9V battery(heavy duty).
Sensor * Sensor is built inside the housing. Power current Approx. DC 8.5 mA.
* Piezoelectric sensor. Weight 345 g/0.76 LB
* Used for dry, non-corrosive and Dimension 185 x 78 x 38 mm
non-ionic air and gas only. ( 7.2 x 3.0 x 1.4 inch )
* Liquid is prohibited. Accessories * Instruction manual............. 1 PC.
Data hold By push button. included * Hard carrying case.............. 1 PC.
ELECTRICAL SPECIFICATIONS ( 23± 5 ℃)
Unit Max. range Resolution Accuracy
m bar 2000 m bar 1 m bar
psi 29 psi 0.01 psi
Kg/cm^2 2.040 Kg/cm^2 0.001 Kg/cm^2 ± 2 % F. S. ( F.S. : full scale )
mm/Hg 1500 mm/Hg 1 mm/Hg
inch/Hg 59.05 inch/Hg 0.02 inch/Hg Note :
meter/H2O 20.40 meter/H2O 0.01 meter/H2O Included linearity, hysteresis and
inch/H2O 802 inch/H2O 0.5 inch/H2O repeatability
Atmosphere 1.974 Atmosphere 0.001 Atmosphere