Showing all 15 results
1200 Amp current probe
Model : CP-1201
* Range : 20 A/200 A/1200 A.
* Output sensitivity :
10 mV/A, 1 mV/A, 0.1 mV/A.
* Output voltage :
200 AcmV ( 20 A. 200 A ), 120 ACmV ( 1200 A ).
* Max. conductor size : 48 mm ( 1.9 inch ) Dia.
* Operation frequency : 50 Hz/60 Hz.
2000 Amp current probe
Model : CP-2000
* Range : 20 A/200 A/2000 A.
* Output sensitivity :
100 mV/A, 10 mV/A, 1 mV/A.
* Output voltage :
2 ACV ( 20 A. 200 A, 2000 A ).
* Max. conductor size : 51 mm ( 2.1 inch ) Dia.
Flexible 3000 Amp current probe
Model : CP-3000-B ( blue connector )
* Range : 30 A/300 A/3000 A.
* Output sensitivity :
100 mV/A, 10 mV/A, 1 mV/A.
* Output voltage :
3 ACV ( 30 A, 300 A, 3000A ).
* Flexible probe length : 600 mm ( 23.6 inch ).
Flexible probe diameter : 15 mm.
Flexible 3000 Amp current probe
Model : CP-3000-R ( Red connector )
* Range : 30 A/300 A/3000 A.
* Output sensitivity :
100 mV/A, 10 mV/A, 1 mV/A.
* Output voltage :
3 ACV ( 30 A, 300 A, 3000A ).
Flexible 3000 Amp current probe
Model : CP-3000-Y ( Yellow connector )
* Range : 30 A/300 A/3000 A.
* Output sensitivity :
100 mV/A, 10 mV/A, 1 mV/A.
* Output voltage :
3 ACV ( 30 A, 300 A, 3000A ).
WATT METER
Model : DW-6060
* WATT ( AC, true power) : 2000 W, 6000 W.
* DCV, ACV, DCA, ACA.
* DC 9 V battery power, 13 mm LCD.
* Size : 180 x 86 x 35 mm.
99.99 x 0.01 W, 520.0 x 0.1 W, PF, ACV, ACA, Signal phase Precision Watt Meter
Model : DW-6063
* 0.01 W resolution, precision Watt meter is special for low power measurement.
* Designed for the high resolution low power measurement.
* Watt, Power factor, ACV, ACA.
* True Power ( watt ) measurement.
* True rms measurement for ACV, ACA.
POWER ANALYZER , bench type
Model : DW – 6090
Large LCD , multi-displays.
True rms for WATT, ACV, ACA.
Watt , VA , Power factor , ACV, ACA , DCV , DCA,
VAr, Whr , ohms, RS232/USB interface.
Accept current probe & CT input . Battery power
SD Card real time data recorder 3 PHASE POWER ANALYZER
Model : DW-6092
* 3 phase/4 wire, 3 phase/3 wire, 1 phase/2 wire, 1 phase /3 wire
* True rms measurement for ACA, ACV.
* True power : W, KW, MW.
* VA, KVA, MVA, VAR, KVAR, MVAR.
* PF ( power factor ), phase angle.
SD Card real time data recorder, complete set 3 PHASE POWER ANALYZER
Model : DW-6093
* Analysis for 3 phase multi-power system, 1P/2W, 1P/3W, 3P/3W, 3P/4W.
* 3 current probes ( CP-1201 ) are included, if change the current probes, the calibration procedures are not necessary.
* Current probe input signal/ranges with selection :
Input signal ( ACA ) : 200 mV/300 mV/500 mV/1 V/2 V/3 V.
Ranges ( ACA ) : 20 A/200 A/2000 A/30 A/300 A/3000 A.
SD Card real time data recorder 3 PHASE POWER ANALYZER, with harmonic measurement
Model : DW-6095
* Analysis for 3 phase multi-power system, 1P/2W, 1P/3W, 3P/3W, 3P/4W.
* 3 current probes ( CP-1201 ) are included, if change the current probes, the calibration procedures are not necessary.
* Current probe input signal/ranges with selection :
Input signal ( ACA ) : 200 mV/300 mV/500 mV/1 V/2 V/3 V.
Ranges ( ACA ) : 20 A/200 A/2000 A/30 A/300 A/3000 A.
0.1 W/1 W WATT/Leakage METER
Model : DW-6160
* Measurement :
Watt ( AC ) : 2500 W x 0.1 W/1 W.
Leakage current ( AC ) : 80.00 mA x 0.01 mA.
ACV : 600.00 V x 0.01 V/0.1 V.
ACA : 10.00 A x 0.001 A/0.01 A.
DCV : 600.0 V x 0.01 V/0.1 V.
6000 W x 1 W, PF, ACV, ACA, Single phase Watt Meter
Model : DW-6163
* True power measurement.
* True rms measurement for ACV, ACA.
* Watt : 0 to 6000 W x 1 W
* Power factor : 0.01 to 1.00 x 0.01 PF.
* ACV : 0 to 600 V X 0.1 V.
POWER CONTROLLER/MONITOR
Model : PWA-6065
* Measurement range ( no cooperate with the external CT and the PT ) :
Watt : 0 to 6,000 Watt.
ACV : 0 to 600 ACV, 40 to 400 Hz.
ACA : 0 to 10 A, 40 to 400 Hz.
* True rms for WATT measurement.
* Current input can cooperate with the external CT ( Current transformer ) such as CT 1000/5A, CT 100/5A …to expand the measurement range.
The PT range can be adjusted with default.
* voltage input can be adjusted with the external PT ( voltage transformer ) to expand the measurement range. The PT range can be adjusted with defaultt.
* Control setting, Hi/Lo alarm setting.
* Control setting relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS232/USB computer interface.