PWA-6065 (POWER CONTROLLER/ MONITOR, RS-232/USB)

 POWER CONTROLLER/MONITOR

Model : PWA-6065

* Measurement range ( no cooperate with the external CT and the PT ) :

  Watt : 0 to 6,000 Watt.

  ACV : 0 to 600 ACV, 40 to 400 Hz.

  ACA : 0 to 10 A, 40 to 400 Hz.

* True rms for WATT measurement.

* Current input can cooperate with the external CT ( Current transformer ) such as CT 1000/5A, CT 100/5A …to expand the measurement range.

  The PT range can be adjusted with default.

* voltage input can be adjusted with the external PT ( voltage transformer ) to expand the measurement range. The PT range can be adjusted with defaultt.

* Control setting, Hi/Lo alarm setting.

* Control setting relay output, alarm relay output.

* Power : 90 ACV to 264 ACV, 50/60 Hz.

* RS232/USB computer interface.

 

AVAILABILITY: out of stock

PRICE : INR
QTY : 0
Delivery Within : 15 TO 20 WORKING DAYS

Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696
Rating Review ()
   
Name :
Email :
Rating :
Name :
Email :
Review :

POWER CONTROLLER/MONITOR
Model : PWA-6065
 
FEATURES
* Professional WATT meter with standard DIN case ( 96 x Setting 1st layer CtLo ( Control low limit )
48 mm ) and Control/Alarm function. Function setting CtHi ( Control high limit )
* Microprocessor circuit ensures high accuracy and procedures ALLo ( Alarm low limit )
provide special functions and features. ALHi ( Alarm high limit )
* Large red LED display, high brightness and easy to read. Second layer CtSt ( CT rate setting )
* Measurement range ( no cooperate the external CT and setting PtSt ( PT rate setting )
the PT ) : procedures CtHy ( Control hysteresis value
Watt : 0 to 6,000 Watt. setting )
* Input signal ( without PT, CT ) : ALHy ( Alarm hysteresis value
ACV : 0 to 600 ACV, 40 to 400 Hz. setting )
ACA : 0 to 10 A, 40 to 400 Hz. Over input " - - - - " mark indication.
* True rms for WATT measurement. Zero Automatic adjustment.
* Current input can cooperate the external CT ( current Adjustment
transformer ) such as CT 1000/5A, CT 100/5A ...to Operating perating 0 to 50 ℃.
expend the measurement range. The CT range can be Temperature
adjusted with default. Operating Less than 80% R.H.
* Voltage input can cooperate the external PT ( voltage Humidity
transformer ) to expend the measurement range. The Power Supply 90 to 260 ACV, 50/60 Hz.
PT range can be adjusted with default. Power Approx. 3.3 VA/AC 110V.
* Control setting, Hi/Lo alarm setting. Consumption Approx. 4.9 VA/AC 220V.
* Control relay output, alarm relay output. * Under no load
* Control Relay will make action when the reading value Weight 261 g/ 0.57 LB.
reach to control value. Dimension DIN size : 96 x 48 mm.
* Alarm Relay will make action when the reading value Panel cut size : 92 x 46 mm.
reach to high/low alarm value. Depth : 110 mm.
* Hysteresis value setting for control and alarm function. Accessories Instruction manual...........................1 PC
* Power : 90 ACV to 264 ACV, 50/60 Hz. Included Case holder with screw.....................2 PCs
* RS232/USB computer interface. Optional USB cable , USB - 01
* Option data acquisition software. Accessories RS232 cable , UPCB - 02
Data Acquisition software SW-U801-WIN
GENERAL SPECIFICATIONS * Real time SD card datalogger
Display Large LED display. 4 digit LED . DL-9602SD
14 mm ( 0.55 inch ) digit height . * GSM controller, GSM-889.
6 indicators . * Interface cable ( cable between meter
PV ( process value ) indicator to GSM-889 ), GMCB-89.
SV ( set value ) indicator
Control out indicator 2-2 Electrical Specifications
Alarm out indicator
Watt indicator Without PT and CT ( direct input )
KW indicator
Circuit Custom chip of microprocessor LSI Range 0 W to 6,000 W
circuit. Resolution 1 W
Watt 0 - 6,000 W. Accuracy ± ( 0.5 % + 5d ) reading
measurement * True power Remark :
* w/o PT. CT. * Measuring Signal come from the rear terminals .
Input signal ACV : 0 to 600 ACV, 40 to 400 Hz. * T11, T15 ACV input : 10 ACV to 600 ACV.
ACA : 0 to 10 A, 40 to 400 Hz. * T16, T15 ACA input : 0.05 ACA to 10 ACA.
* w/o PT. CT. * Accuracy is test under input signal is sine wave, 50/60 Hz.
Sampling Time Approx. 0.8 second. * ACV, ACA frequency response is from 40 to 400 Hz
Relay Output Number 2 relays * Watt measurement is True RMS value.
Function Relay 1 : * Accuracy value is specified within 23℃ ± 5℃
Control relay.
Relay 2 : With PT and CT
High/Low alarm relay.
Max load 0.5 ACA/250 ACV Range 0 to 999.9 KW
0.5 DCA/24 DCV Resolution 0.1 KW
* Do not apply the relay Accuracy ± ( 0.5 % + 5d ) reading
contact load current Remark :
> 0.5 A, other wise the * Measuring Signal come from the rear terminals .
relay may be damaged * T11, T15 ACV input : 10 ACV to max. 600 ACV.
permanently without PT ( Potential transformer ) adjust value : x 1 to x 100.
warranty. * T16, T15 ACA input : 0.05 ACA to 10 ACA.
Data Output RS232 / USB PC Computer interface. CT ( current transformer ) adjust value : x 1 to x 200.
* Connect the optional RS232 cable , * Accuracy is test under input signal is sine wave, 50/60 Hz.
UPCB - 02 will get the RS232 plug. * Accuracy is specified for the meter only, not include the accuracy
* Connect the optional USB cable, of CT ( current transformer ) and the PT ( potential transformer ).
USB - 01 will get the USB plug.
 



RECENTLY VIEWED PRODUCTS