AM-4237SD (SD CARD DATA RECORDER, AIR VELOCITY, AIR FLOW, HUMIDITY/ TEMP, TYPE K/J TEMP,RS-232/USB)

 SD card real time data recorder Air velocity, Air flow, Humidity, Dew point, Type K/J Temp.

ANEMOMETER
 
Model : AM-4237SD
* Real time data logger, save the data into the SD memory card and can be downloaded to the Excel, extra software is no need.
 
* Air velocity/Temp. measurement, professional.
 
* 0.4 to 25.0 m/s, ft/min., km/h. knots, mile/h.
 
* Air flow : CMM, CFM.
 
 
 
 
AVAILABILITY: In stock

PRICE : INR 18170.00
QTY : 1
Delivery Within : 15 TO 20 WORKING DAYS

Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696
Rating Review ()
   
Name :
Email :
Rating :
Name :
Email :
Review :

SD Card real time data recorder Humidity/Temp., type K/J Temp., Air flow

ANEMOMETER
 
Model : AM-4237SD
FEATURES
* Two probes are included : Power Current Normal operation ( w/o SD card save
Anemometer probe and Humidity/Temp. probe. data and LCD Backlight is OFF) :
* 3 in 1 : Anemometer, Humidity/Temp. meter, Type J/K Approx. DC 15 mA.
thermometer. When SD card save the data and LCD
* ABS plastic vane pobe, heavy duty. Backlight is OFF) :
* Air velocity : m/S, Ft/min, Km/h, Knots, Mile/h, Approx. DC 36 mA.
* Air temperature ( ℃, ℉ ) Weight 347 g/ 0.76 LB. * Meter only
* Air flow : CMM, CFM. Dimension Main instrument :
* Low-friction ball vane wheels make sure high accuracy 182 x 73 x 47.5 mm
in high & low velocities. ( 7.1 x 2.9 x 1.9 inch )
* Type K, Type J thermocouple thermometer. Anemometer sensor head :
* Air Temp. used thermistor sensor, fast response time. Round, 72 mm Dia.
* Humidity/%RH : 10 to 95 %RH. Humidity Probe :
* Dew point. Wet bulb Temp.. 197 mm ( 7.8 inch ) in length.
* Real time SD memory card Datalogger, it Built-in Clock Accessories * Instruction manual...........................1 PC
and Calendar, real time data recorder , sampling time set Included * Anemometer probe.......................... 1 PC
from 1 second to 3600 seconds. * Humidity probe................................1 PC
* Manual datalogger is available ( set the sampling * Hard carrying case ( CA-06 ).............1 PC
time to 0 ), during execute the manual datalogger Optional SD Card ( 2 G )
function, it can set the different position ( location ) No. Accessories Type K thermocouple probe.
( position 1 to position 99 ). AC to DC 9V adapter.
* Innovation and easy operation, computer is not need USB cable, USB-01.
to setup extra software, after execute datalogger, just RS232 cable, UPCB-02.
take away the SD card from the meter and plug in the Data Acquisition software,SW-U801-WIN.
SD card into the computer, it can down load the all the Excel Data Acquisition software,SW-E802.
measured value with the time information (
year/month/date/ hour/minute/second ) to the Excel ELECTRICAL SPECIFICATIONS (23± 5 ℃)
directly, then user can make the further data or graphic
analysis by themselves. Air velocity
* SD card capacity : 1 GB to 16 GB.
* LCD with green light backlight, easy reading. Measurement Range Resolution Accuracy
* Can default auto power off or manual power off. m/S 0.4 - 25.0 m/s 0.1 m/S ± ( 2%+0.2 m/S)
* Data hold, record max. and min. reading. Km/h 1.4 - 90.0 km/h 0.1 Km/h ± ( 2%+0.8 Km/h)
* Microcomputer circuit, high accuracy. mph ( Mile/h ) 0.9 - 55.9 mile/h 0.1 mph ± ( 2%+0.4 mph)
* Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter. Knots 0.8 - 48.6 knots 0.1 Knots ± ( 2%+0.4 Knots)
* RS232/USB PC COMPUTER interface. FPM ( Ft/min ) 80 - 4930 ft/min 1 FPM ± ( 2%+40 FPM)
* Separate probe, easy for operation of different
measurement environment. Air temperature
* Wide applications: use this anemometer to check air
conditioning & heating systems, measure air velocities, Measuring Range 0 ℃ to 80 ℃/32 ℉ to 176 ℉
wind temperature...etc. Resolution 0.1 ℃/0.1 ℉
Accuracy 0.8 ℃/1.5 ℉ ( < 60 ℃ )
GENERAL SPECIFICATIONS Air flow
Circuit Custom microprocessor LSI circuit.
Display LCD size : 52 mm x 38 mm Measurement Range Resolution
LCD with green backlight ( ON/OFF ). CMM ( m^3/min. ) 0 to 63,000 CMM 0.001 to 1 CMM
Function Anemometer ( Air velocity, Air flow ). CFM ( ft^3/min. ) 0 to 2,224,900 CFM 0.001 to 100 CFM
Humidity/Temp. meter.
Type J/K thermometer. Measurement Area
Measurement Air velocity : CMM ( m^3/min. ) 0.001 to 30.000 m^2
Unit m/S (meters per second) CFM ( ft^3/min. ) 0.01 to 322.93 ft^2
Km/h ( kilometers per hour )
Ft/min ( FPM, feet per minute ) Humidity/ Temperature
Knots ( nautical miles per hour )
Mile/h ( mph, miles per hour ) Range 5 % to 95 % R.H.
Air temperature :℃, ℉ Humidity Resolution 0.1 % R.H.
Air flow : CMM, CFM. Accuracy ≧70% RH :
Humidity/Temp. : %RH/℃ or ℉. ± (3% reading + 1% RH).
Dew point ( Humidity ) : ℃ or ℉. < 70% RH :
Wet bulb ( Humidity ) : ℃ or ℉. ± 3% RH.
Type K/ Type J thermometer : ℃, ℉ Range 0 ℃ to 50 ℃,32 ℉ to 122 ℉.
Datalogger Auto 1, 2, 5, 10, 30, 60, 120, 300, Temperature Resolution 0.1 degree
Sampling Time 600, 1800 3600 second. Accuracy ℃ ± 0.8 ℃.
Setting range @ Sampling time can set to 1 second, ℉ ± 1.5 ℉.
but memory data may loss.
Manual Push the data logger button Dew Point ( Humidity )
once will save data one time.
@ Set the sampling time to ℃ Range -25.3 ℃ to 48.9 ℃
0 second. Resolution 0.1 ℃
@ Manual mode, can also select the ℉ Range -13.5 ℉ to 120.1 ℉.
1 to 99 position ( Location ) no. Resolution 0.1 ℉.
Memory Card SD memory card. 1 GB to 16 GB. Remark :
Advanced * Set clock time ( Year/Month/Date, * Dew Point display value is calculated from the
setting Hour/Minute/ Second ) Humidity/Temp. measurement automatically.
* Decimal point of SD card setting * The Dew Point accuracy is sum accuracy value of
* Auto power OFF management Humidity & Temperature measurement..
* Set beep Sound ON/OFF
* Set thermometer type to Type K or Type J Wet bulb ( Humidity )
* Set temperature unit to ℃ or ℉
* Set sampling time ℃ Range -21.6 ℃ to 50.0 ℃
* SD memory card Format Resolution 0.1 ℃
Temperature Automatic temp. compensation for the type ℉ Range -6.9 ℉ to 122.0 ℉.
Compensation K/J thermometer. Resolution 0.1 ℉.
Data Hold Freeze the display reading. Remark :
Memory Recall Maximum & Minimum value. *Wet bulb display value is calculated from the
Sampling Time Approx. 1 second. Humidity/Temp. measurement automatically.
of Display * The Welt bulb accuracy is sum accuracy value of
Data Output RS 232/USB PC computer interface. Humidity & Temperature measurement..
* Connect the optional RS232 cable
UPCB-02 will get the RS232 plug. Type K/J thermometer
* Connect the optional USB cable
USB-01 will get the USB plug. Sensor Resolution Range Accuracy
Operating 0 to 50 ℃. Type
Temperature * meter only Type K 0.1 ℃ -50.0 to 1300.0 ℃ ± ( 0.4 % + 0.5 ℃ )
Operating Less than 85% R.H. -50.1 to -100.0 ℃ ± ( 0.4 % + 1 ℃ )
Humidity 0.1 ℉ -58.0 to 2372.0 ℉ ± ( 0.4 % + 1 ℉ )
Power Supply * AAlkaline or heavy duty DC 1.5 V battery -58.1 to -148.0 ℉ ± ( 0.4 % + 1.8 ℉ )
* Battery ( UM3, AA ) x 6 PCs, or equivalent. Type J 0.1 ℃ -50.0 to 1200.0 ℃ ± ( 0.4 % + 0.5 ℃ )
-50.1 to -100.0 ℃ ± ( 0.4 % + 1 ℃ )
Power Supply * ADC 9V adapter input. ( AC/DC power 0.1 ℉ -58.0 to 2192.0 ℉ ± ( 0.4 % + 1 ℉ )
* ACV adapter is optional ). -58.1 to -148.0 ℉ ± ( 0.4 % + 1.8 ℉ )
PATENT CHINA : ZL 2008 2 0189918.5 ZL 2008 2 0189917.0 TAIWAN : M 358970 M 359043
Germany : Nr. 20 2008 016 337.4 JAPAN : 3151214 U.S.A. : Pending.
 