RCB-220V (RCCB CHECKER, 220V)

 RCCB CHECKER

Model : RCB-220V, 200 ~ 240 ACV, 50/60 Hz.

* Checking the power soocket pin assignment.

* Residual current circuit breaker test.

* Rated tipping current setting 10 mA, 30 mA, 100 mA, 300 mA, 500 mA.

AVAILABILITY: In stock

PRICE : INR 7360.00
QTY : 1
Delivery Within : 15 TO 20 WORKING DAYS.

Warning: mysql_fetch_assoc() expects parameter 1 to be resource, boolean given in /home1/wacoins2/public_html/includes/docker7.php on line 696
Rating Review ()
   
Name :
Email :
Rating :
Name :
Email :
Review :

 RCCB CHECKER

Model : RCB-220V
Model : RCB-110V
 
FEATURES
* It is used for quick checking of the pin assignment of a safety socket as well as for
verification of the RCCB with the 5 rated tripping current settings of 10 mA,
30 mA, 100 mA, 300 mA and 500 mA.
* Phase detection and phase inversion.
* Indication of plug assignment via 3 LEDs.
* Display of tripping pulse current for residual currents.
* Operated without battery, direct power supply from the mains socket to be tested.
* Handy & compact ABS plastic housing case.
GENERAL SPECIFICATIONS
Display 3 LEDs for pin assignment of sockets L-N, L-PE, N-PE.
1 LED for tripping current pulse.
(L-Line, N-Neture, PE-Power Earth)
Applications * Checking the shock-proof plug pin assignment
* Residual Current Circuit Breaker Test
Rated Tripping 10 mA, 30 mA, 100 mA, 300 mA and 500 mA.
Current Settings
Test Current Duration Approx. 140 ms (200 ms, -30%) according to DIN VDE.
Operating Factor Approx. 10% for 500 mA range, wait approx. 10 sec between
each step.
Tested Mains Model : RCB-220V 200V to 240V, 50/60 Hz
Voltage Model : RCB-220V 100V to 120V, 50/60 Hz
Power Supply Directly from mains.
Operating Temp. 0 to 50 ℃ (32 to 122 ℉).
Operating Humidity Less than 80% RH.
Weight 200 g/0.44 LB.
Dimension 180 x 72 x 32 mm (7.1 x 2.8 x1.3 inch).
Accessories Instruction manual................................................1 PC.
Included Power cable with Plug.......................................... 1 PC.
APPLICATIONS
Checking the shock-proof plug pin Residual Current Circuit Breaker
assignment Test
L-PE L-N N-PE ....ON ....OFF Measuring Procedures :
........correct connection 1. If "L" and "N" inverted, then may
........L and N inverted inverse conductors "L" & "N" by using
........PE missing select the "Phase Polarity Switch".
........N missing 2. Select desired tripping current by using
........L missing select the "Tripping Current Switch".
........L and PE inverted 3. Trigger the RCCB by pressing the
* If the socket is wired correctly, then the "Test Button".
diodes "L-N" and "L-PE" are illuminated.
 